  干式调平地暖设计要点

来源:http://www.jn-langkun.com/ 发布时间:2022/02/05

  干式调平地暖设计要点
 
  Key points of dry leveling floor heating design
 
  1.干法调平地面采用防潮阻燃的可调节龙骨和玻镁均热板组合固定,标准龙骨宽50厚35,均热板厚度12,基础厚度48,可调节高度30,地面抗压强度≥1.2吨/平方,每两延米平整度≤3mm,可调节龙骨的距为300mm。
 
  1.The dry leveling ground is fixed with moisture-proof and flame-retardant adjustable keel and glass magnesium soaking plate.The standard keel is 50 wide and 35 thick,the soaking plate is 12 thick,the foundation thickness is 48,the maximum adjustable height is 30,the ground compressive strength is≥1.2 tons/square,the flatness of every two linear meters is≤3mm,and the center distance of adjustable keel is 300mm.
 
  2.干式地暖设计:普通地暖区采用环保地楞型干式地暖模块,有架空间隙和养身健康需求的,选用远红外功能型模块;根据热源设备和水温选择合适的地暖管,低温热源应选择管间距加密的辐射末端,可确保良好的地暖温度;采用远红外功能模块可消除架空层地暖的积热非环保隐患。其中⑴为张干式地暖模块合理定位。
 
  2.Dry type floor heating design:environmental friendly floor ridge type dry type floor heating module is adopted in ordinary floor heating area.If there is space gap and health needs,far-infrared functional module is selected;Select appropriate floor heating pipes according to heat source equipment and water temperature,and select high-efficiency radiation ends with dense pipe spacing for low-temperature heat source to ensure good floor heating temperature;The use of far-infrared function module can eliminate the heat accumulation and non environmental hidden danger of overhead floor heating.(1)is the first dry floor heating module with reasonable positioning.
 
  3.管线分离区设计:管线分离沿墙边预留布管,消除了管道交叉隐患,采用沟槽木楞骨,便于布线和固定承载保护板。根据线管布置密度,分别预留600mm和300mm两档沟槽木楞骨,不影响地暖效果。
 
  3.Design of pipeline separation area:the pipeline separation is reserved along the wall to eliminate the hidden danger of pipeline crossing.The grooved wooden ridge is adopted to facilitate wiring and fixing the bearing protection plate.According to the layout density of the line pipe,two grooves of 600mm and 300mm are reserved respectively,which will not affect the floor heating effect.
 
  4、卫生间干式地暖设计:采用35mm厚防锈铝板免地楞干式地暖模块干贴地砖,或采用2CM厚平板地暖模块湿贴地砖;按照标准工艺铺设可根除窜水隐患,竣工地面比过道低10mm。
 
  4.Dry floor heating design of toilet:35mm thick antirust aluminum plate free floor ridge dry floor heating module is used for dry floor tiles,or 2cm thick flat floor heating module is used for wet floor tiles;Laying according to the standard process can eliminate the hidden danger of water channeling,and the finished ground is 10mm lower than the aisle.
 
  5.分水器安装在厨房或卫生间干区,过门的地暖管不大于4路,其余管路宜采用背出安装。
 
  5.The water separator shall be installed in the dry area of the kitchen or toilet.The floor heating pipe passing through the door shall not be more than 4 ways,and the other pipelines shall be installed back out.
 
  6、干式地暖配置锅炉温控器安装在主卧室,选配房间温控器,实现预约开关和房间温度自动控制。
 
  6.The boiler temperature controller for dry-type floor heating is installed in the master bedroom,and the room temperature controller is selected to realize the reservation switch and automatic control of room temperature.
 
  7、在均热保护板表面干贴地砖,或铺设地板。
 
  7.Dry paste floor tiles on the surface of soaking protection board or lay floor.